Caddx Dl900 Software

Open page wide FAX TO: Customers FROM: Caddx Technical Support SUBJECT: Modem Setup DATE: Monday, December 11, 2006 Contact if you would like to receive the software via e-mail. All these changes pertain to the setup screen of the DL900 software.

Caddx Dl900 Software

Modem setup for the Windows version and Setup for the DOS version. DOS: First check the COM port settings. Leave the initialization string at the bottom at the default S7=255S10=255X0T and see if it dials with the COM port setting you entered.

Try changing just COM 1 to 4 since all zeros in address and IRQ will look up the default. If you have an unusual setting such as COM 3 IRQ 5 then change the IRQ setting to match. If you need to enter the address it uses a leading zero, e.g. These settings can be checked in Control panel, then Modems, then the Diagnostics tab then More Info or Query Modem. Windows: select the modem in the top 'Connect using' line of the Modem setup screen. Most external modems are not detected and shown by Windows.

Now you can easily search and download everything from product technical documents to service manuals and other reference materials.

Caddx DL900 Programming Downloader Software Find, download and program any Caddx DL900 security alarm panels with the Caddx DL900 downloader software for programming. Eqppgevv qvjg rcpgn # p[eqoocykvjkpvjgrjqpgpwodgtyknnetgcvgc ugeqpfrcwug 2ctgpvjgugu j[rjgpu cpfurceguctgkipqtgf 6jgceeqwpvpwodgtowuvdgwpkswghqtgcejceeqwpv +vpggfpqvdgvjg. Dl900 software user manual. Type programfiles in the run field and click OK. Don 8217 t worry about running to the store for more food and missing any of.

Go to Control and select Modems or Phone and Modem Options then add the modem on those screens. Once the modem is dialing and the panel is answering any of the following changes may be necessary to allow your modem to work with our controls.

In all the following modem commands there are no letter Os, only the number zero. Check your modem manual to find which commands are valid for your modem. For speaker control - not needed for Windows version L0 or L1- Low speaker volume L2- Medium speaker volume L3- High speaker volume M0- Speaker off M1- Speaker on until carrier detected M2- Speaker always on To help connect &FE0- Reset to factory defaults, MUST be at the beginning of the string. Use this if other software might be leaving the modem setup in unexpected way.

For the Windows version place &F at the beginning of init. String one(1).

&C1 - Set carrier to follow panel carrier. (Usually the default) S9=1 - Reduce carrier detect time. This may help with a consistent 'Unable to receive STATUS ' message.

(This command has been made permanent part of the setup for versions 3.72 and later so you don't need it here any more) B1 - Switch to US frequencies. (Bell) Also B16 for Bell 103 in some modems if supported. S7=255 - This is the time to wait for the panel to answer. It can be lowered to a minimum of about 100 for panels that answer on the 8th ring. S10=255 - This is time for loss of carrier. It must remain above 220.

We recommend only 254 or 255. X0 - Allows dialing without dial tone. Not necessary when using phone lines. T - Touch Tone dialing. Adobe Photoshop Font File Location. Change to P if pulse dialing is needed.

To help when the modem will not hang up properly &D2 - Modem DTR signal forces hang-up. (Usually the default) To downgrade fast modems &Q0 - Straight asynchronous mode. &K0 - Disable flow control. S37=3N0 - Fix at 300 baud. F1 - Fix at 300 baud. Shorthand for above if supported. N1 - Direct operating mode.

Try this first. Q0 - Disable serial port flow control G0 - Disable modem port flow control J0 - BPS rate adjust disable%C0 - Disable MNP 5 compression%E0 - Disable auto-retrain. Helpful if you get 'Control has answered' but no farther with a fast modem. Here are specific initialization strings on some modem models that other dealers have worked with and now have operating properly. All commands use only the number zero (0) NOT the letter Oh (O). The default string is S7=255S10=255X0T. NOTE: If your modem is 33.6 or faster and it is not on this list, try the following initialization strings first: 1) S7=255S10=255X0T N1S37=3N0 2) S7=255S10=255X0T+MS=B103 300 and 1200 Baud Modems 1) Hayes Smartmodem 300 S7=255S10=255T (No 'X0') 2) #Hayes Smartmodem 1200 external S7=255S10=255X0T 3) Hayes Smartmodem 1200B internal S7=255S10=255X0T 4) #Practical Peripherals 1200 SA mini S7=255S10=255X0T Securcomm S7=255S10=255X0T (Only the Hayes Smartmodem 1200, Okidata Okitel 1200 and Hyundai 1200 automatically provide tone answer machine defeat.